100% USA Origin |
Brooks Vietnam |
SLAMF63 Thermal Mass Flow Meter |
Replaced by: SLAMF63S3ABA0G2A1A5D1AA1F |
Digital I/O. Communications S: Smart Emulation (Analog and/or RS485) |
Mechanical Connections 3A: DIN DN15 PN40 |
O-ring Material B: Buna |
Valve Seat Material A: None (Meter) |
Valve Type 0: None |
Analog I/O G: 4-20mA I/O (PG11 Cable Gland) |
Power Supply 2: +24 Vdc |
Output Enhancement A: Standard Setting / Response Time |
Certification 1: Standard Location (Safe Area) |
Valve Orifice Size: A No Orifice |
Mass Flow Restrictor Type 5: LFE |
Flow Restrictor Size D: Size D |
Calibration conditions 1: Single S-series calibration |
OEM Code A: Standard Brooks Label |
Software Revision A: Revision A |
Mounting Attitute 1: Horizontal base down |
Baudrate F: 19200 |
Customer Process: |
Fluid: CO2 |
Normal Upstream Pressure: 18 bar-g |
Meter Specifications: |
Meter Flow (Full Scale): 40 kg/hr |
Reference Temp : 21.1 degC |
Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS) |
Max Pressure Ratin: 70 bar-g |
Max Temperature: 65 °C |
Ingress Protection: IP66 |
SLAMF63S3ABA0G2A1A5D1AA1F voi IP 66 |
Note: IP 66 tot hon IP65 |
(SLA5863S3ABA0C2A1A5D1AA |
IP65) |
100% USA Origin |
Brooks Instrument Vietnam |
Model Code: SLA5853S2CAB2B2A1 |
SLA5853 Mass Flow Controller |
Digital I/O, Communication S: Smart Emulation (analog or RS-485) |
Mechanical Connection 2C: 3/8” Compression |
O-ring material A: Viton |
Valve Seat material B: Viton |
Valve Type 2: Normally Close |
Analog I/O B: 0-5 Volt |
Power Supply 2: +24 Vdc |
Output Enhancement A: Standard Setting / Response time |
Certification 1: Standard Location |
* Customer Process Data: |
Fluid: Air |
Upstream Pressure: 5-10 kg/cm2-g |
Downstream Pressure: Customer to advice |
* Meter Specifications: |
Meter Range (Full Scale): 500 slpm |
Ref Temperature: 70 degF |
Accuracy: +/- 1% Rate |
Max Pressure Rating: 100 bar g |
Max Temperature: 65 °C |
NOTE: Please confirm whether it is ln/min, lst/min or la/min that you need. |
(Brooks Instrument mass flow controller for nitrogen and air. |
– Flow rate: 0 – 500 lit/minute |
– Compress air about 5 – 10 kg/cm2 |
– I/O digital signal can controlled by computer. |
– Material for flow meter is metal) |
100% USA Origin |
Brooks Vietnam |
SLAMF63 Thermal Mass Flow Meter |
Replaced by: SLAMF63S3ABA0G2A1A5D1AA1F |
Digital I/O. Communications S: Smart Emulation (Analog and/or RS485) |
Mechanical Connections 3A: DIN DN15 PN40 |
O-ring Material B: Buna |
Valve Seat Material A: None (Meter) |
Valve Type 0: None |
Analog I/O G: 4-20mA I/O (PG11 Cable Gland) |
Power Supply 2: +24 Vdc |
Output Enhancement A: Standard Setting / Response Time |
Certification 1: Standard Location (Safe Area) |
Valve Orifice Size: A No Orifice |
Mass Flow Restrictor Type 5: LFE |
Flow Restrictor Size D: Size D |
Calibration conditions 1: Single S-series calibration |
OEM Code A: Standard Brooks Label |
Software Revision A: Revision A |
Mounting Attitute 1: Horizontal base down |
Baudrate F: 19200 |
Customer Process: |
Fluid: CO2 |
Normal Upstream Pressure: 18 bar-g |
Meter Specifications: |
Meter Flow (Full Scale): 40 kg/hr |
Reference Temp : 21.1 degC |
Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS) |
Max Pressure Ratin: 70 bar-g |
Max Temperature: 65 °C |
Ingress Protection: IP66 |
SLAMF63S3ABA0G2A1A5D1AA1F voi IP 66 |
Note: IP 66 tot hon IP65 |
(SLA5863S3ABA0C2A1A5D1AA |
IP65) |
100% USA Origin |
Brooks Vietnam |
0254 Read Out & Control |
Code: 0254AA2B23A |
Type Housing: Panel Mount Kit |
Power Cord For Power Supply: European Power Cord For 220 VAC |
Power Supply Output Voltage: + 24 VDC |
Input/Output Pinout and Signal Adapters: Current Pinout / Voltage Pinout Adapter Set |
Options: RS-232 cable, 3 meter, 9 pin Female “D” |
OEM Code: Standard Brooks Labelling |
|
|
|