Fully Automated Chemistry Analyzer
Artos Magnum 400
INNOVATION DESIGN SMART COMBINATION
400 test per hour-Time Efficiency
Automated testing & Low Maintenance-Operation Efficiency 150ul reagent consumption-Cost Efficiency
Swemed Biomedicals Pvt. Ltd.3
Site No.11, Sy. No.29/1, 29/2, First Floor, Chunchanaghatta Cross
Yelachenahalli, Kanakapura Road, B'lore – 560 062, India
Reagent tray
-60 reagent positions
-Non-stop cooling system with peltier pad inside, 24 hours 2oC-14oC.
-Barcode reader(optional)
Sample tray
-100 sample positions, micro cup &test tube can be used.
-Barcode reader(optional)
Reaction tray
-80 reaction cuvettes
-Reaction volume as low as 150 ul
-Stable & acctare temprature (37+ 0.1oC) for reaction
High Precision ceramic syringe
-Sample dispensing by frequency converting design
-Premannent ceramic piston
-Accurate dispensing as low as 0.1 ul
-Sample Volume :2-30ul, step by 0.1ul
-Reagent Volume:10-300ul, step by 1ul
Sample probe
-External & internal mirror polish, external & internal probe
-Washing(reduuce carry-over)
-Dedicated sampling probe equipped with sensitive liquid sensor, timely feedback of reagent &sample residuals
-Collision protection
-Automatic probe depth adjusting
Excellent mixer design
-Teflon coating mixer.No water dropping (reducing carry-over)
-Excelent mixing effect with standard mixing procedure
Washing station
-7 needles wash-station
-Twice washing
-Effective washing to ensure accurate result and vaild diagnostics
Powerful Software
-User friendly software interface simple, easy-to-operation
-Sample automatic dilution(decrease, increase, normal)
-Masking tests when reagent or standard is exhausted
-Calibration auto-dilution Linear & nonlinear calibration
-Multi-points calibration up to 8 point
-Quality control apply to Westgard, L-T plot, Cumulative
-Automatic dilute and re-test when absorbance range is ut of range
-Automatic dilute and re-test when linear limit is out of range Automatic dilute and re-test when linear range is out of range Freely set the auto dilute ratio and dilute water position
-Real-time display of running status
-Real-time display of status of reagent tary, sample tray and reaction tray
Real-time updating of reagent residuals Real-time marking of defective cuvette
-Reaction result automatic checking and warning
-Calibration result automatic cheking and warning
-Alarm log:Automatic alarm and record in alarm list with explanations during running process
Operation system requirements
Operation system : Windows Xp, Windows7, Windows8 , Windows10
USB
Swemed Biomedicals Pvt. Ltd.
Tell:+9198-86-069862 Email:info@swemedbio.com
Site No.11, Sy. No.29/1, 29/2, First Floor Chunchanaghatta Cross
, Yelachenahalli, Kanakapura Road, B'lore – 560 062, India
Contact:
Ms.Ngoc Ha
DEPARTMENT SALE.
Telephone: +84 - 08.38.42.12.15
Mobile: +84 - 0909.03.86.98.
Email: Sale03@mdscorp.com
Website: mdsgroup.vn
MDS Electronic & Biotechnology Company Limited.
Add: 95/20 Pho Quang St, 2 Ward, Tan Binh District, Ho Chi Minh city, Viet Nam Country.