Fully Automated Chemistry Analyzer
Artos Magnum 400 SWEMED
*Reagent tray
-60 reagent positions
-Non-stop cooling system with peltier pad inside, 24 hours 2oC-14oC.
-Barcode reader(optional)
*Sample tray
-100 sample positions, micro cup &test tube can be used.
-Barcode reader(optional)
*Reaction tray
-80 reaction cuvettes
-Reaction volume as low as 150 ul
-Stable & acctare temprature (37+ 0.1oC) for reaction
*Sample probe
-External & internal mirror polish, external & internal probe
-Washing(reduuce carry-over)
-Dedicated sampling probe equipped with sensitive liquid sensor, timely feedback of reagent &sample residuals
-Collision protection
-Automatic probe depth adjusting
*Excellent mixer design
-Teflon coating mixer.No water dropping (reducing carry-over)
-Excelent mixing effect with standard mixing procedure
*Washing station
-7 needles wash-station
-Twice washing
-Effective washing to ensure accurate result and vaild diagnostics
*High Precision ceramic syringe
-Sample dispensing by frequency converting design
-Premannent ceramic piston
-Accurate dispensing as low as 0.1 ul
-Sample Volume :2-30ul, step by 0.1ul
-Reagent Volume:10-300ul, step by 1ul
*Powerful Software
-User friendly software interface simple, easy-to-operation
-Sample automatic dilution(decrease, increase, normal)
-Masking tests when reagent or standard is exhausted
-Calibration auto-dilution Linear & nonlinear calibration
Multi-points calibration up to 8 point
Quality control apply to Westgard, L-T plot, Cumulative
Automatic dilute and re-test when absorbance range is out of range
Automatic dilute and re-test when linear limit is out of range Automatic dilute and re-test when linear range is out of range Freely set the auto dilute ratio and dilute water position
Real-time display of running status
Real-time display of status of reagent tary, sample tray and reaction tray
Real-time updating of reagent residuals Real-time marking of defective cuvette
Reaction result automatic checking and warning Calibration result automatic cheking and warning
Alarmlog: Automaticalar mandrecor dinalarm list with explanations during running process
*Technical specifications
1. General information
Machine type: Random Access, open reagent
Test speed: Constand 400Test/Hour
Test Princeple: Colorimetric method, turbidimetry
Test methos: 1 point end, 2 point end, fixed time , kinetics
Calibration Type: Linear & nonlinear
2. Sample & reagent unit
Sample tray: 100 Sample positions
Sample cup tupe: Micro cup & test tube
Reagent tray: 60 reagent positions
Sample volume: 2-30 ul, step by 0.1 ul
Reagent volume: 10-300 ul, step by 1ul
Sample & reagent bar code reader
3. Optical system
Light source: Halogen lamp
Wavelength: 340nm, 405nm, 450nm, 505nm, 546nm, 578nm, 620nm, 660nm, 690nm
Absorbance range: 0-4.0 Abs
Resolution: 0.0001Abs
4. Reaction unit
Reaction tray: 80 high quality plastic cuvettes
Reaction volume: 150 – 350 ul
Reaction time: 10 minutes
Temperature: Peltier pad incubation system reaction temperature (37+0.1oC)
Cuvette washing: 2*6 step automatic washing